M. K. Gubaidullina, A. E. Urusov, A. V. Zherdev, C. Xu, B. B. Dzantiev

Immunochromatographic test systems using the conjugate anti-species antibodies – colloid gold: features and benefits on the example of determination of ochratoxin A

Abstract

In the present work, new format of immunochromatographic analysis with indirect labeling was compared with a traditional analysis for the case of ochratoxin A (OTA). In the proposed scheme specific antibodies are included in the dilution buffer, while the anti-species antibody conjugate with the marker is applied to the test strip. The assay is realized for the detection of OTA in maize extracts. The indirect labeling reduces the detection limit of OTA by two orders of magnitude (up to 0.12 ng/mL). The reasons for this gain are considered. The approach can be applied to various low molecular weight compounds.
Key words: immunoassay, test-strips, colloidal gold, antibody – nanoparticle complexes, mycotoxins.